Dry Type Transformer with OLTC
RANGE : Upto 5000 KVA in 11 KV Class.
General Information
We offer innovatively propelled scope of Dry Type VPI (Vacuum Pressure Impregnated) Transformers with Off Circuit Tap Links (up to 5000 KVA in 11 KV Class.), utilizing CRGO M3 to M5 MOH Lamination and Electrolytic Grade 99.9% unadulterated copper. These transformers are intended for inconvenience free execution, with low power loss and low noise. Utilization of present day fabricating methods and ideal use of dynamic materials guarantees cost viability, dependability and a long inconvenience free execution.
Our Ventilated Dry Type Transformer are fitted in fenced in area for Indoor establishments and are absolutely upkeep free and safe from flame as the material utilized is metal, clay, NOMEX and other non inflammable material. In Dry Type Transformer as there is no oil, hence maintenance is distinctly less demanding and there is no way of spillages and there is negligible nontoxic smoke if there should be an occurrence of flame. Utilization of Class "F"/"H" protection expands the warmth bearing limit and empowers the utilization of the transformer in damp and artificially contaminated environment.
Application
Our products are widely used in the following areas:
- Furnaces
- Test Rooms
- Research Stations
- Paper Industries
- Electroplating
- Electrolytic Processes
- Hotels
- Hospitals
- Tea Gardens
- Defence Installations
- Space Research Centers
- IT Industries
- Steel Plants
- Cement Factories
- Glass Works
- Chemical Industries
- Plastic Processes
- Capacity :Up to 5000 KVA
- No. of Phases :3 Phase
- Frequency :50 Hz.
- Voltage Range :11 KV
- Tapping :Off Circuit Tap Links for ± 5% Taps on H.T. Side in steps of 2.5% each..
- Insulation :Class 'H'
- Vector Group :Dyn 11
- Duty Cycle :Continuous
- Winding :Copper Wound
- Terminals :As per required
- Winding Temperature Indicator :Cable Box H.V / LV Side
- Lifting lugs :Uni directional rollers
- Low replacement cost.
- Undistorted output characteristics ie. no wave from distortion.
- Moving parts on L.T. side and it’s mass is extremely low, only few lb-inch torque.
- Energy savings.
- High efficiency (about 99%) and minimum no load losses.
- Simplicity and flexibility of design
- On load stepless voltage variation
- Long service life
- Impulse tested
- Regulating coils are wound with rectangular conductors on their edge, thus giving high mechanical strength compared to other designs.
- Capacity :Up to 5000 KVA
- No. of Phases :3 Phase
- Frequency :50 Hz.
- Voltage Range :11 KV
- Tapping :Off Circuit Tap Links for ± 5% Taps on H.T. Side in steps of 2.5% each..
- Insulation :Class 'H'
- Vector Group :Dyn 11
- Duty Cycle :Continuous
- Winding :Copper Wound
- Terminals :As per required
- Winding Temperature Indicator :Cable Box H.V / LV Side
- Lifting lugs :Uni directional rollers
- Low replacement cost.
- Undistorted output characteristics ie. no wave from distortion.
- Moving parts on L.T. side and it’s mass is extremely low, only few lb-inch torque.
- Energy savings.
- High efficiency (about 99%) and minimum no load losses.
- Simplicity and flexibility of design
- On load stepless voltage variation
- Long service life
- Impulse tested
- Regulating coils are wound with rectangular conductors on their edge, thus giving high mechanical strength compared to other designs.