Oil Cooled Distribution & Power Transformer
RANGE : Up to 10000 KVA in 11 and 33 KV Class
General Information
The distribution & power transformers are used for converting electrical energy with higher voltage to lower voltage. Generally the higher voltage falls in the range of 11-22-33kV whereas lower voltage falls in 250 or 433V range. The frequency remains identical before and after the transformation of the current.
All the distribution & power transformers are approved by reputed National Inspecting Agencies like Engineers India Limited, RITES, Department of Industries, Haryana, CIL, SGS, CPWD, NIT and many other bodies.
Application
Our products are widely used in the following areas:
- Furnaces
- Test Rooms
- Research Stations
- Paper Industries
- Electroplating
- Electrolytic Processes
- Hotels
- Hospitals
- Tea Gardens
- Defence Installations
- Space Research Centers
- IT Industries
- Steel Plants
- Cement Factories
- Glass Works
- Chemical Industries
- Plastic Processes
- Capacity :Up to 10000 KVA
- No. of Phases :3 Phase
- Frequency :50 Hz.
- Voltage Range :11 KV/ 33KV
- Tapping :Either +- 5% tapping will be provided with OFF circuit in steps of 2.5% OR on load Load Tap Changer to provide +5% to -15% Taps in steps of 1.25% on H. T. Side. Transformer tappings may be provided as per custom requirement.
- Insulation :Class 'A' (for Dry Type Trf.)
- Vector Group :Dyn 11
- Duty Cycle :Continuous
- Winding :Copper Wound
- Terminals :Custom Request
- Rating & Diagram plate :Earthing terminals
- Lifting lugs :Thermometer pocket
- Oil Conservator with drain plug :Air release hole with plug
- Oil Level indicator :Explosion vent with diaphragm
- Top-filter Valve :Inspection cover.
- Silica gel breather :Drain –cum-bottom-filter valve
- Cooling radiators :Uni / Bi- directional rollers
- Low replacement cost
- Undistorted output characteristics ie. no wave from distortion.
- Moving parts on L.T. side and it’s mass is extremely low, only few lb-inch torque.
- Energy savings.
- High efficiency (about 99%) and minimum no load losses.
- Simplicity and flexibility of design
- On load stepless voltage variation
- Long service life
- Impulse tested
- Regulating coils are wound with rectangular conductors on their edge, thus giving high mechanical strength compared to other designs.
- Capacity :Up to 10000 KVA
- No. of Phases :3 Phase
- Frequency :50 Hz.
- Voltage Range :11 KV/ 33KV
- Tapping :Either +- 5% tapping will be provided with OFF circuit in steps of 2.5% OR on load Load Tap Changer to provide +5% to -15% Taps in steps of 1.25% on H. T. Side. Transformer tappings may be provided as per custom requirement.
- Insulation :Class 'A' (for Dry Type Trf.)
- Vector Group :Dyn 11
- Duty Cycle :Continuous
- Winding :Copper Wound
- Terminals :Custom Request
- Rating & Diagram plate :Earthing terminals
- Lifting lugs :Thermometer pocket
- Oil Conservator with drain plug :Air release hole with plug
- Oil Level indicator :Explosion vent with diaphragm
- Top-filter Valve :Inspection cover.
- Silica gel breather :Drain –cum-bottom-filter valve
- Cooling radiators :Uni / Bi- directional rollers
- Low replacement cost
- Undistorted output characteristics ie. no wave from distortion.
- Moving parts on L.T. side and it’s mass is extremely low, only few lb-inch torque.
- Energy savings.
- High efficiency (about 99%) and minimum no load losses.
- Simplicity and flexibility of design
- On load stepless voltage variation
- Long service life
- Impulse tested
- Regulating coils are wound with rectangular conductors on their edge, thus giving high mechanical strength compared to other designs.